Production information
High efficiency and low standby power consumption compliant with ErP directive Lot6, fanless ATX power supply! |
|||||
![]() |
• Low standby power consumption compliant with ErP directive Lot6 • High efficiency An actual measurement value at 50% load: 87.3% at 115 VAC input, 89.0% at 240 VAC input • Longer than 10 years expected lifetime design even fanless power supply at 30 deg.C, 170W, 24 consecutive hours operation • Min. load current 0A for all outputs • Capacitor package available for instantaneous power failure measure (Optional) • Mounted with an optional FAN, it outputs continuous rated 305W max. A terminal for optional FAN is equipped • Detachable output harness |
||||
| Continuous
170W
|
Peak
400W
|
||||
| *Please use Metric Screw Threads, ("M3" screws) for PSU mounting.(Inch Screw Threads cannot be used.) | |||||
Output specification
| Compatible case size | 1U size | |
| Outline drawing | 106Wx37Hx225D | |
| Weight | 0.65 kg typ | |
| Input Voltage | AC | 85-264V |
| Efficiency | AC | 82% typ(AC100V)/85% typ(AC240V) |
| Power factor | 96% min. (100 VAC), 90% min. (240 VAC) | |
| Input changeover system | Worldwide | |
| Safety | UL60950, CSA60950 (c-UL) acquired CE Marking (IEC62368-1) ,PSE Compliant |
|
| High frequency current regulation | IEC61000-3-2 (Ver 2.1) Class D compliant | |
| EMI standard (Input feedback noise) |
VCCI-B, FCC-B, CISPR22-B, EN55022-B compliant | |
| CE marking | LVD,EMC,rohs2.0 | |
| EMS immunity | EN61000-4-2 compliant EN61000-4-11 compliant EN61000-4-8 compliant EN61000-4-6 compliant EN61000-4-5 compliant EN61000-4-4 compliant EN61000-4-3 compliant |
|
| MTBF | 100,000H min. | |
| Operating temperature | 0 to 60 deg.C | |
| Leakage current | 1.0mA max. (100 VAC) / 2.0mA max. (200 VAC) / 2.4mA max. (240 VAC) | |
| Cooling systems | Air-cooling without blower | |
| Insulation | AC input - FG/DC output: 1500 VAC for 1 minute | |
| Output ground connection | Connected chassis | |
| Warranty | 3 years after delivery. If any faults belong to us, the defective unit shall be repaired or replaced at our cost |
|